Hand-foot-clothing contamination monitor

Ensure precision in nuclear safety with advanced contamination detection for beta and gamma emitting isotopes, crucial for maintaining sterile environments in healthcare settings.

The VLB-303-2 and VLB-303-2-ST from Comecer are innovative hand-foot-clothing radiation monitors developed for rigorous contamination detection in nuclear medicine, radiopharmacy, and healthcare sectors. Integrated with patented plastic scintillation detectors, these monitors excel in measuring beta and gamma radiations, ensuring safety compliance. The VLB-303-2 model features dual scintillation detectors, including a detachable hand detector for clothing and targeted foot measurements. In contrast, the VLB-303-2-ST adds a NaI thyroid detector and a GM tube-based stomach activity detector for enhanced monitoring of additional isotopic exposure. Automated with VERA 303 software, these systems facilitate user data management via RFID badges, enabling efficient tracking and generating detailed contamination and risk analysis reports. Constructed with robust stainless steel, they stand out for their compact footprint and ease of maintenance, assuring reliable operation in high-demand laboratory and safety environments. The monitors meet stringent environmental safety standards, making them ideal for institutions needing precise radiocontamination management.

Benefits

  • Ensures regulatory compliance by accurately detecting beta, gamma, and alpha radiocontaminants on personnel.
  • Enhances safety with comprehensive monitoring, reducing contamination risk in sensitive areas.
  • Facilitates efficient data management and reporting through VERA 303 software integration.
  • Supports flexible use with detachable and interchangeable detector functionality.
  • Durable stainless steel construction ensures long-lasting performance and minimal maintenance.

General


Applications
Cell,Gene therapy,Healthcare,Radiopharmacy,Hospital pharmacy,Nuclear medicine
End products
Personal protective equipment (ppe) monitoring,Radioisotopes,Diagnostic tracers,Radiopharmaceuticals,Contamination detection reports,Therapeutic radiopharmaceuticals
Steps before
Calibration,User Badge Setup,System Initialization,RFID Badge Preparation
Steps after
Data Analysis,Report Generation,Risk Assessment
Input ingredients
beta emitting isotopes,gamma emitting isotopes,user badges,detection data
Output ingredients
measurement reports,risk analysis reports,user measurement data,alarms summary
Market info
Comecer is known for manufacturing advanced containment and isolation systems, particularly in the pharmaceutical and nuclear medicine sectors, with expertise in custom-engineered equipment, ensuring high safety and compliance standards.

Technical Specifications


Detection technology
Failure-safe plastic scintillation detectors
Detector types
Plastic scintillation detectors,NaI detector
Detector functionalities
Measures beta and gamma isotopes
Panel control
Touch screen control panel
Software type
VLB-303 software
Data management
Easy-to-use
Footprint
Small
Material
Stainless steel surface
Additional detectors
End-filter GM tube for stomach,NaI detector for thyroid
Database connection
Ethernet connection
RFID reader integration
Yes
Measurement initiation
RFID badge scanning

Operating Characteristics


Measurement Capability
Beta and gamma emitting isotopes
Automation level
Manual/Automatic with RFID
Footprint
Small
Detector Type
Plastic scintillation detectors
Screen Control
Touch screen control panel
Software
VLB-303,VERA 303 software
Report Generation
Automatic via VERA 303
Data Management
PC connected via Ethernet
Access Control
RFID badge system
Detector Configuration
Double-sided hands,foot,stomach,thyroid detectors
Contamination Detection
Hand,foot,clothing,stomach,thyroid
Versatility
Detachable hand detector for clothing
Protection
Collimator protection foil for feet detectors

Material Compatibility


Abrasion resistance
High
Biological compatibility
Yes
Cleanability
Easy to clean
Corrosive resistance (e.g. acids)
High resistance
Density/particle size
Not specified

Physical Characteristics


Compact footprint
Small
Control Panel Type
Touch screen

Custom Options


Control panel type
Touch screen control panel
Detection options
Plastic scintillation detectors,NaI detector,end-filter GM tube