Laboratory series steam sterilizers

Ensure the sterility of your labware and culture media with reliable steam-based sterilization, optimized for precise control and enhanced safety features to prevent contamination and equipment hazards.

The MOST-L Laboratory Series Steam Sterilizers from Shinva are designed to meet the rigorous demands of laboratories, pharmaceutical factories, and medical care units. These sterilizers are distinctive for their clamshell-type automatic door and microcomputer-controlled operation, offering seamless integration into both existing and new laboratory setups. They cater to the sterilization needs of labware, culture mediums, and materials in contact with blood, essential for maintaining safety and compliance in scientific research.

The machine operates with a unique water circulation system that ensures no steam exhausts during the process, thus preventing aerosol generation and ensuring operator safety. With 108 programmable options across laboratory, medical, and custom categories, the sterilizers provide unparalleled flexibility in process control, making them suitable for a wide range of applications including the preparation of culture broths, saline solutions, and sterilization of surgical instruments.

The inclusion of safety interlocks, such as overtemperature and overpressure protection, alongside water quality testing, ensures reliable and safe operation. Additionally, optional features like dual-temperature control, rapid cooling, and data recording with electronic storage enhance operational efficiency. These features, coupled with options for configuring temperature control and load handling, make the MOST-L Steam Sterilizers a versatile choice for professionals seeking robust and efficient sterilization solutions in their production line.

Benefits

  • Enhances safety by eliminating steam exhaust to prevent aerosols and lab injuries.
  • Offers flexibility with 108 customizable programs for diverse sterilization needs.
  • Ensures reliable operation with comprehensive safety interlocks and water quality monitoring.
  • Increases efficiency with optional rapid cooling, reducing process time significantly.
  • Facilitates remote monitoring and data logging for streamlined process management.
Applications
Medical devices,Laboratory equipment,Scientific research,Labware,Culture medium,Liquid preparations,Disease control,Inspection departments,Sterilization,Blood contact materials,Pharmaceuticals
End products
Laboratory media,Iv bags,Vials,Saline solutions,Culture broths,Beakers,Laboratory glassware,Serum bottles,Blood sample containers,Petri dishes,Test tubes,Surgical instruments,Cell culture flasks,Reagents,Pipettes,Biohazardous waste containers,Biological specimens,Agar plates
Steps before
Preparation of labware,Media preparation,Collection of unsealed liquids,Pre-cleaning,Sorting materials for sterilization
Steps after
Quality control and inspection,Drying,Packing,Labeling,Storage
Input ingredients
labware,culture medium,unsealed liquid,preparation materials,materials contacting blood,materials contacting body fluid
Output ingredients
sterilized labware,sterilized culture medium,sterilized liquid,sterilized preparation materials,safe materials
Steam-discharge Control
Rapid,Slow,Zero
Program Types
108 programs (lab,medical,custom)
Microcomputer control
Automatic,LCD display
Water Quality Testing
Tank inspection and user prompt
Automatic Protection Devices
Overtemperature,Dry burning-resistant
Pressure-relieving Device
Automatic
Electrical Protection
Overvoltage and overload
Door Structure
Clamshell-type Automatic
Cooling System
Rapid cooling option
Door Safety Interlocking
Electronic lock structure
Electronic Storage
U-disk,special software
Remote Monitoring
Tablet PC
Data Recording
Mini-printer
Drying System
Rear thermal-drying
Internal Circulation
No steam exhaust
Door Type
Clamshell-type Automatic Door
Operation System
Microcomputer Automatic Control
Water Quality Monitoring
Yes
Program Types
108 Programs in Three Categories
Steam-discharge Control
Rapid,Slow,Zero
Steam Exhaust
No Steam Exhaust
Safety Interlocking
Yes
Pressure-relieving
Automatic
Cooling Lock
Yes
Remote Monitoring
Tablet PC
Data Recording
Mini-printer,U-disk Storage
Drying System
Rear Thermal-drying System
Density/particle size
0.5–2.5 g/cm³ / 50–1000 µm
Door Type
Clamshell-type Automatic Door
Machine Footprint
N/A
Material
Stainless Steel
Internal Chamber Size
N/A
External Dimensions
N/A
Water Tank Capacity
N/A
Condensing System
Internal
Control Panel Type
Microcomputer Automatic Control with LCD Display
Probe Type
Mobile Probe for Dual-temperature Control
Control panel type
Microcomputer automatic control with LCD text display
Door structure
Clamshell-type Automatic Door
Door safety interlocking device
Electronic lock structure
Steam-discharge control
Adjustable discharge velocity
Optional Functions
Dual-temperature Control System,Drying System,Enclosed Liquid Sterilization Function,Rapid Cooling Function
Data Recording
Mini-printer,electronic storage,remote monitoring
Market info
Shinva is known for manufacturing medical equipment, including sterilization and disinfection devices, radiotherapy products, and diagnostic imaging systems, demonstrating expertise in healthcare solutions and a strong reputation for quality in the medical industry.